HyPrecision Predictive waterjet pump Operator Manual 810120 175
7 – Troubleshooting
Troubleshooting
Controller problems
Input/output status
This screen shows all inputs and outputs on the controller. Green shows enabled status. Gray shows not enabled
status. These can be helpful for troubleshooting.
This table describes the assigned inputs and outputs.
I1
Hydraulic fluid level
l2
Hydraulic fluid temperature is higher than 55°C (131°F)
I3
Hydraulic fluid temperature is higher than 65°C (149°F)
I4
Hydraulic fluid temperature is higher than 45°C (113°F)
l5
Not used
l6
Front intensifier left proximity switch
l7
Front intensifier right proximity switch
l8
Not used
l9
SMI address 0
l10
SMI address 1
l11
SMI operating out
l12
SMI fault
l13
Not used
l14
Not used
l15
Controls on
I16
Remote mode on
l17
Remote pump on
l18
Remote pump off
l19
Remote cooling on
l20
Remote pierce-pressure on
l21
Primary motor fault
l22
Primary motor on
l23
Boost pump on
I24
Heat exchanger fan on