180 HyPrecision Predictive waterjet pump Operator Manual 810120
8 – Pump specifications
Pump specifications
HyPrecision P-15
Dimensions and weights
The shipping weight is for the pump, the pallet, and the packaging. Exact weights are measured at shipment.
Operating weight is for an unpackaged pump with hydraulic fluid.
Electrical
The pump uses 3-phase alternating current (AC) electricity. Some parts, such as valve solenoids and sensors,
use 24-volt direct current (VDC) electricity from a power supply in the electrical enclosure.
Water
Length 178 cm (70 in.) Shipping weight 1,100 kg (2,400 lb)
Width 86 cm (34 in.) Operating weight 1,000 kg (2,200 lb)
Height 140 cm (55 in.)
11 kW, 15 hp
50 Hz 60 Hz
Voltage 400 V 208 V to 230 V 460 V
Full-load current 24.9 A 45.8 A to 41.6 A 20.8 A
Primary circuit breaker rating 25.0 A 50.0 A 25.0 A
Minimum Maximum
CUTTING WATER IN
Flow
3.8 L/minute
(1 gallon/minute)
—
Pressure
2.8 bar
(280 kPa / 40 psi)
7. 6 b ar
(760 kPa / 110 psi)
CUTTING WATER OUT
Flow
—
1.1 L/minute
(0.3 gallon/minute)
Pressure
345 bar
(34,500 kPa / 5,000 psi)
4,140 bar
(414,000 kPa / 60,000 psi)
Cut pressure factory setpoint
—
4,140 bar
(414,000 kPa / 60,000 psi)
Pierce pressure factory
setpoint
1,380 bar
(138,000 kPa / 20,000 psi)
—
COOLING IN and COOLING OUT
Flow
11.4 L/minute
(3 gallons/minute)
—
Pressure
2.8 bar
(280 kPa / 40 psi)
7. 6 b ar
(760 kPa / 110 psi)