8 – Pump specifications
Pump specifications
Compressed air
Air pressure that is too low can prevent the bleed-down valve from closing and can cause the intensifier to
overstroke.
Air pressure that is too high can cause damage to the needle and the seat in the bleed-down valve.
Minimum Maximum
Flow
4.8 bar
(70 psi)
5.5 bar
(80 psi)