HyPrecision Predictive waterjet pump Operator Manual 810120 45
2 – Product description
Product description
Intensifier
Low-pressure supply water goes into the intensifier, where it is pressurized for piercing and cutting.
The hydraulic center section contains hydraulic fluid, which is used to compress water in the high-pressure ends.
The pressurized water exits the high-pressure end through a check valve and goes to the attenuator.
Attenuator
The piston stroking in the hydraulic center section of the intensifier causes a brief change of water pressure. The
attenuator compensates for high-pressure water fluctuations and maintains a consistent output pressure.
The 2-liter attenuator has a guard installed. The attenuator guard is intended to keep personnel safe from studs or
end caps, which can become projectiles if the attenuator fails.
Bleed-down valve
The bleed-down valve is a normally open, air-actuated dump valve. The valve releases high-pressure water from
the system when the pump is turned off or when the operator changes from cut mode to pierce mode.
1
Intensifier
2
Attenuator
3
Bleed-down valve
1
High-pressure end
2
Hydraulic center section