Machine Interface Receptacle with Voltage Divider Board
12 809940 Field Service Bulletin Powermax45 XP
Set the voltage divider PCB
The factory setting on the voltage divider PCB is 50:1.
To change the voltage divider to a different setting, set the DIP switches to one of the following:
NOTICE
The voltage divider PCB is a simple resistive divider of raw arc voltage. To prevent ground loops and
electrical interference, you must isolate the divided arc signal.
NOTICE
The factory-installed voltage divider PCB supplies a voltage that is in proportion to the arc voltage. The
DIP switch settings on the voltage divider PCB control the output in open circuit conditions, to a
maximum output of 16 V. This output is an impedance-protected, functional extra-low voltage (ELV)
output. This type of output prevents shock, energy, and fire under normal conditions at the machine
interface receptacle and in single-fault conditions with the machine interface wiring. The voltage divider
PCB is not fault tolerant and ELV outputs do not comply with safety extra-low voltage (SELV)
requirements for direct connection to electrical devices.
L1
X12
R1
R2
R3
R7
R5
R6
R4
C3
C2
C1 C4
L1
BLK
RED
J1
J3
J4
RED
BLK
J2
21.1 30
40
50
GRN
S1
ALL DOWN = 20
D1
J5
20:1 21.1:1 30:1 40:1 50:1