Rack Options
Part Number Description Information
28L4707 Netfinity Rack Keyboard Tray Supports Keyboards in racks, also used with Flat Panel Monitor Rack Mount Kit II
28L36xx
1
Space Saver II Keyboard 1U, includes TrackPoint IV, requires Rack Keyboard Tray P/N 28L4707
94G7444 Monitor Compartment
T3347xx
2
E51 Color Monitor 9U, requires Monitor Compartment P/N 94G7444
T31U2xx
2
E54 Color Monitor 9U, requires Monitor Compartment P/N 94G7444
T32U3xx
2
E74 Color Monitor 10U, requires Monitor Compartment P/N 94G7444
T274Axx
2
G78 Color Monitor 10U, requires Monitor Compartment P/N 94G7444
37L6888 Flat Panel Monitor Rack Mount Kit II Requires Rack Keyboard Tray P/N 28L4707
11AG1xx
2
T54A Flat Panel Color Monitor 3U, requires Flat Panel Monitor Rack Mount Kit II P/N 37L6888
28L0542 Console Server Selector Switch (4-port)
6
1U, mounts in sidewall compartments, EIA space, or Monitor Compartment
94G7445 Console Server Selector Switch (8-port)
7
1U, mounts in sidewall compartments, EIA space, or Monitor Compartment
09N4290 NetBAY 1 x 4 Console Switch
6
1U, mounts in sidewall compartments, EIA space, or Monitor Compartment; supports one to four
servers, one console
09N4291 NetBAY 2 x 8 Console Switch
7
1U, mounts in sidewall compartments, EIA space, or Monitor Compartment; supports one to
eight servers, two consoles (only one console when installed in the Monitor Compartment
09N4293 NetBAY Console Cable Set - 2.1m (7ft) Connects servers to console switch
94G7447 NetBAY Console Cable Set - 3.7m (12ft) Connects servers to console switch
2PDUxxx
3
200-240V Power Distribution Unit
8
1U, 200-240V, 16A, mounts in sidewall compartment or EIA space, 10 IEC 320-C13 outlets
37L68xx
4
NetBAY Rack PDU
8
1U, 100-240V, 15A, mounts in sidewall compartment or EIA space, 7 IEC 320-C13 outlets
37L68xx
5
NetBAY Server Dual-cord PDU 1U, 100-240V, 15/10A, mounts in sidewall compartment or EIA space, 4 IEC 320-C13 outlets
37L6885 NetBAY 200-240V Single-phase Front-end PDU) 1U, 200-240V, shared 20A, mounts in sidewall compartment, 3 IEC 320-C19 outlets
37L6887 NetBAY 3-phase Front-end PDU) 1U, 200-415V, shared 30A, mounts in sidewall compartment, 3 IEC 320-C19 outlets
14RIxxx
3
APC Smart-UPS 1400RMiB 3U, 220-240V, four - 10 Amp, IEC 320-C13 outlets
30RIxxx
3
APC Smart-UPS 3000RMiB 3U, 220-240V, eight - 10 Amp IEC 320-C13 and one -16 Amp IEC 320-C19 outlets
37L6862 APC Smart-UPS 5000RMB 5U, 220-240V, eight - 10 Amp IEC 320-C13 and two -16 Amp IEC 320-C19 outlets
94G7446 Rack Attachment Kit Used to attach Rack cabinets together P/N 9306900 and/or P/N 9306910 - to make into a suite
94G6669 Side Panel Kit Used with Rack P/N 9306900 only
94G6670 Blank Filler Panel Kit Consists of one 5U, one 3U, and two 1U blank filler panels
94G7442 Fixed Shelf Supports equipment weighing up to a total of 45Kg
94G7448 Rack Power Cord -Type C12 IEC 320-C13 to IEC 320-C14 3.7m (12ft)
1. Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian, 50=Spanish, 51=UK English, 44=US English, and P/N 19K3831=Switzerland, 19K3832=Sweden/Finland,
19K3833=Portugal, 19K3834=Belgium, 19K3836=Russia, 19K3837=Poland.
2. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy, SD=Saudi Arabia, SA=South Africa, CH=Switzerland, UK=UK, EU=Europe.
3. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark, ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland, UKM=United Kingdom, EUR=Europe.
4. Where ‘xx’ represents the appropriate country code as follows:- 66=US/Saudi Arabia, 68=EU, 70=Denmark/Switzerland, 72=Israel, 74=Italy, 76=South africa, P/N 06P6028=UK.
5. Where ‘xx’ represents the appropriate country code as follows:- 65=US/Saudi Arabia, 67=EU, 69=Denmark/Switzerland, 71=Israel, 73=Italy, 75=South africa, P/N 06P6027=UK.
6. Console Server Selector Switch P/N 28L0542 was withdrawn with effect from 15/01/01 - and is replaced by NetBAY 1x4 Console Switch P/N 09N4290.
7. Console Server Selector Switch P/N 94G7445 was withdrawn with effect from 15/01/01 - and is replaced by NetBAY 2x8 Console Switch P/N 09N4291.
8. 200-240V Power Distribution Unit P/N 2PDUxxx was withdrawn with effect from 15/01/01 - and is replaced by NetBAY Rack PDU P/N 37L68xx.