EasyManuals Logo
Home>IBM>Server>eServer xSeries

IBM eServer xSeries User Manual

IBM eServer xSeries
127 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
37
Updated
28/02/01
xSeries 240 / Netfinity 5600 Memory Configurator
Total Memory
1
Quantity of RDIMMs Added
256MB
(1 x 256)
Models
128MB
(33L3058)
256MB
(33L3060)
512MB
(33L3062)
1GB
(33L3064)
384MB 1 - - -
512MB 2 or 1 - -
640MB 3 - - -
768MB - 2 or 1 -
1024MB - 3 - -
1280MB - - 2 or 1
1792MB - - 3 -
2048MB - - 4
2
-
2304MB - - - 2
3328MB - - - 3
4096MB
(max)
2
- - - 4
2
This table does not represent all possible memory configurations.
1. Network Operating Systems may limit the maximum amount of addressable memory. See
operating system specifications for further information.
2. Requires removal of standard memory.
Part Number Memory Description
1
33L3058 128 MB, 133 MHz SDRAM ECC RDIMM
33L3060 256 MB, 133 MHz SDRAM ECC RDIMM
33L3062 512 MB, 133 MHz SDRAM ECC RDIMM
33L3064 1 GB, 133 MHz SDRAM ECC RDIMM
1. Install largest RDIMM in socket 4 (J1) with subsequent RDIMMs in the
following order: J4, J3, J2.
xSeries 240 / Netfinity 5600 Internal Hard Disk Drive (HDD) and External Storage Configurator
Total Int.
Storage
1
7200 RPM Ultra160 SCSI HDDs 10,000 RPM Ultra160 SCSI HDDs 15,000 RPM Ultra160 SCSI
HDDs
9.1 GB
(P/N 37L7201)
2
18.2 GB
(P/N 37L7202)
2
36.4 GB
(P/N 37L7203)
2
9.1 GB
(P/N 37L7204)
2
18.2 GB
(P/N 37L7205)
2
36.4 GB
(P/N 37L7206)
2
9.1 GB
(P/N 19K0655)
2
18.2 GB
(P/N 19K0656)
2
0 GB 0GB Standard on Base Models 0GB Standard on Base Models 0GB Standard on Base Models
9.1 GB 1 - - 1 - - 1 -
18.2 GB 2 or 1 - 2 or 1 - 2 or 1
27.3 GB 3 - - 3 - - 3 -
36.4 GB 4 or 2 or 1 4 or 2 or 1 4 or 2
45.5 GB 5 - - 5 - - 5 -
54.6 GB 6 or 3 - 6 or 3 - 6 or 3
72.8 GB - 4 or 2 - 4 or 2 - 4
91 GB - 5 - - 5 - - 5
109.2 GB - 6 or 3 - 6 or 3 - 6
145.6 GB - - 4 - - 4 - -
182 GB - - 5 - - 5 - -
218.4 GB
(max.)
--6--6--
This table does not represent all possible hard disk drive (HDD) configurations.
1. Select a total storage row then select the quantity of HDDs from a column corresponding to the HDD of choice. Total Internal Storage listed is within +/- 0.2 GB unless otherwise noted.
2. xSeries 240 / Netfinity 5600 contains an Ultra2 hot-swap backplane which limits Ultra160 HDDs to Ultra2 bus speeds.
R
R
R
R
Install largest RDIMM in
socket 4 (J1) with
subsequent RDIMMs in
the following order: J4,