7. To Install a disk unit using dedicated maintenance perform the following:
a. Power off the expansion unit. See Expansion unit power procedure.
b. Disconnect the power cord.
c. Put the disk unit part-way into the desired slot and rotate the handle of the disk unit towards you.
d. Push the disk unit completely into the slot and rotate the handle towards the disk unit to latch it into
the slot.
e. Replace the covers that were removed during this procedure and return to the procedure that sent
you here.
This ends the procedure.
FC 5095, FC 0595 - Display panel - NB1
For use by authorized service providers.
Use this procedure to remove or install the display panel - NB1 on an FC 5095, FC 0595.
To remove or replace the display panel - NB1:
1. Open the front cover.
2. Power off the expansion unit. Expansion unit power procedure.
3. Remove the front cover. See FC 5095, FC 0595 - Covers.
4. Remove the ac power cord on the expansion unit you are working on.
5. Pull the locks on each side of the display panel.
6. Slide the display panel out approximately half way and remove the cables from the rear of the panel.
7. Remove the display panel.
8. Install the display panel by reversing this procedure. After exchanging an item, go to Verify the repair.
This ends the procedure.
FC 5095, FC 0595 - Power distribution backplane - PB1
For use by authorized service providers.
Use this procedure to remove or replace the power distribution backplane - PB1 in an FC 5095, FC 0595.
To remove or replace the power distribution backplane - PB1:
1. Power off the expansion unit. See the Expansion unit power procedure.
2. Remove the rear and side covers. Ssee FC 5095, FC 0595 - Covers.
3. Remove the power supplies. See FC 5095, FC 0595 - Power supply - P01 and P02.
4. Disconnect the power cable that goes to the backplane SB1.
5. Remove the screws that secure the power cage to the base of the expansion unit.
6. Remove the screws that secure the power cage to the power distribution backplane.
7. Remove the SPCN cable from the channel in the power cage.
8. Remove the power cage by lifting it out of the expansion unit.
9. Remove the screws that secure the power distribution backplane to the expansion unit.
10. Remove the power distribution backplane by lifting it out of the expansion unit.
11. Install the power distribution backplane by reversing this procedure. After exchanging an item, go to
Verify the repair.
This
ends the procedure.
FC 5095, FC 0595 - Power supply - P01 and P02
For use by authorized service providers.
Use this procedure to remove or replace the power supply P01 and P02 on an FC 5095, FC 0595.
198 Hardware (Remove and Replace; Part Locations and Listings)

Table of Contents

Other manuals for IBM iSeries 810

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 810 and is the answer not in the manual?

IBM iSeries 810 Specifications

General IconGeneral
BrandIBM
ModeliSeries 810
CategoryServer
LanguageEnglish

Related product manuals