EasyManuals Logo
Home>IBM>Server>System x3100 M4 Type 2582

IBM System x3100 M4 Type 2582 Problem Determination And Service Guide

IBM System x3100 M4 Type 2582
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #285 background imageLoading...
Page #285 background image
8. Install the hard disk drive fan duct (see “Installing the hard disk drive fan duct”
on page 215).
9. Rotate the rear adapter-retention bracket to the closed (locked) position.
10. Stand the server back up in its vertical position.
11. Install and lock the side cover (see “Installing the side cover” on page 167).
12. Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
Important: Perform the following updates:
v Either update the server with the latest RAID firmware or restore the pre-existing
firmware from a diskette or CD image.
v Update the UUID (see “Updating the Universal Unique Identifier (UUID)” on page
286).
v Update the DMI/SMBIOS (see “Updating the DMI/SMBIOS data” on page 289).
v Clear the CMOS data (see JP1 in “System-board switches and jumpers” on page
19).
Chapter 5. Removing and replacing server components 265

Table of Contents

Other manuals for IBM System x3100 M4 Type 2582

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3100 M4 Type 2582 and is the answer not in the manual?

IBM System x3100 M4 Type 2582 Specifications

General IconGeneral
BrandIBM
ModelSystem x3100 M4 Type 2582
CategoryServer
LanguageEnglish

Related product manuals