8. Install the hard disk drive fan duct (see “Installing the hard disk drive fan duct”
on page 215).
9. Rotate the rear adapter-retention bracket to the closed (locked) position.
10. Stand the server back up in its vertical position.
11. Install and lock the side cover (see “Installing the side cover” on page 167).
12. Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
Important: Perform the following updates:
v Either update the server with the latest RAID firmware or restore the pre-existing
firmware from a diskette or CD image.
v Update the UUID (see “Updating the Universal Unique Identifier (UUID)” on page
286).
v Update the DMI/SMBIOS (see “Updating the DMI/SMBIOS data” on page 289).
v Clear the CMOS data (see JP1 in “System-board switches and jumpers” on page
19).
Chapter 5. Removing and replacing server components 265