System-event/error log messages
The system-event/error log contains POST messages and messages generated by
a Remote Supervisor Adapter II SlimLine, if one is installed. The system-even/error
log can contain messages of three types:
Information Information messages do not require action; they record significant
system-level events, such as when the server is started.
Warning Warning messages do not require immediate action; they indicate
possible problems, such as when the recommended maximum
ambient temperature is exceeded.
Error Error messages might require action; they indicate system errors,
such as when a fan is not detected.
Each message contains date and time information, and it indicates the source of
the message (POST/BIOS or the service processor).
In the following example, the system-event/error log message indicates that the
server was turned on at the recorded time.
-------------------------
Date/Time: 2002/05/07 15:52:03
DMI Type:
Source: SERVPROC
Message Code: System Complex powered Up
Message Code:
Message Data:
Message Data:
-------------------------
The following table describes the possible system-event/error log messages and
suggested actions to correct the detected problems.
Note: These actions have the following meanings:
Reseat the system board
(Trained service technician only) Complete the following steps:
1. Disconnect all cables from the system board.
2. Remove all removable components from the system board, including
the microprocessor; then, remove the system board from the chassis
(see “Removing the system board” on page 64).
3. Check the system board for damage or loose parts.
4. Make sure that the system board area in the chassis is free of objects;
then, replace the system board in the chassis (see “Installing the
system board” on page 65).
5. Reinstall all removable components on the system board and reconnect
all cables to the system board.
Reseat the power supply
Complete the following steps:
1. Remove the power supply from the server (see “Removing the power
supply” on page 46).
2. Check the power supply for damage and for crimped or damaged
cables.
3. Install the power supply in the server (see “Installing the power supply”
on page 47).
104 IBM System x3250 Types 4364, 4365, and 4366: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3250 4364 and is the answer not in the manual?

IBM System x3250 4364 Specifications

General IconGeneral
BrandIBM
ModelSystem x3250 4364
CategoryServer
LanguageEnglish

Related product manuals