11. Reinstall the ServeRAID adapter (see “Installing an adapter” on page 79)
12. Close and lock the left-side cover (see “Installing the left-side cover” on page
108)
13. Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 104.
Removing a PCI-X riser-card assembly
To remove a PCI-X riser-card assembly, complete the following steps:
1. Read the safety information that begins in Safety and “Installation guidelines”
on page 36.
2. Turn off the server (see “Turning off the server” on page 24) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables from the server.
3. Disconnect all external cables and power cords.
4. Carefully turn the server on its side so that it is lying flat, with the cover facing
up.
Attention: Do not allow the server to fall over.
5. Unlock and remove the left-side cover (see “Removing the left-side cover” on
page 39)
6. Remove the adapter if one is installed on the PCI-X riser-card assembly (see
“Installing an adapter” on page 79).
7. Press the release latch that secures the PCI-X riser-card assembly from the rear
side of the server chassis.
372 System x3300 M4 Type 7382: Installation and Service Guide