Front fan cage
Complete the following steps to remove the front fan cage.
Fan cage assembly
Fan cage assembly
release buttons
1. Read the safety information that begins on page vii and “Handling
static-sensitive devices” on page 57.
Attention: Static electricity that is released to internal server components
when the server is powered-on might cause the server to halt, which might
result in the loss of data. To avoid this potential problem, always use an
electrostatic-discharge wrist strap or other grounding system when you work
inside the server with the power on.
2. Remove the fans (see “Hot-swap fan” on page 63).
3. Press the fan cage release latches on each side of the fan cage toward the
sides of the server. The cage will lift up slightly when the release latches are
fully open.
4. Grasp the cage and lift it out of the server.
To install the front fan cage, complete the following steps:
1. Align the guides on the fan cage with release latches on each side.
2. Push the cage into the server until it clicks into place.
3. Install the fans (see “Hot-swap fan” on page 63).
Rear fan cage
If you have installed a redundant power supply, you also installed a fan cage on the
rear of the server.
64 IBM System x3500 Type 7977: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3500 and is the answer not in the manual?

IBM System x3500 Specifications

General IconGeneral
BrandIBM
ModelSystem x3500
CategoryServer
LanguageEnglish

Related product manuals