4-4 SOFTWARE ADJUSTMENT
Select an operation using [CH-UP] / [CH-DN] keys, then set specified value using [RPT/BASE] / [MONI] keys on the FRONT
PANEL.
1
2
1
2
1
2
LCD display : A06 HW POWER
Operating freq. : 162.2750 MHz
Connect an RF power meter to the [TX]
antenna connector.
Transmitting
LCD display : A06 LW POWER
Operating freq. : 162.2750 MHz
Transmitting
LCD display : A07 LW M DEV
Operating freq. : 162.2750 MHz
IF bandwidth : Wide
Connect an audio generator to the [MIC]
jack through the JIG cable and set as:
1.0 kHz/40 mVrms
Set an FM deviation meter as:
HPF : OFF
LPF : 20 kHz
De-emphasis: OFF
Detector : (PP)/2
Transmitting
LCD display : A08 LW LMODC
Operating freq. : 150.2750 MHz
IF bandwidth : Wide
Connect an audio generator to the [MIC]
jack through the JIG cable and set as:
1.0 kHz/40 mVrms
Set an FM deviation meter as:
HPF : OFF
LPF : 20 kHz
De-emphasis: OFF
Detector : (PP)/2
Transmitting
LCD display : A09 LW HMODC
Operating freq. : 173.725 MHz
Transmitting
LCD display : A10 LW CTCDEV
Operating freq. : 162.2750 MHz
Set the FM deviation meter as:
HPF : OFF
LPF : 20 kHz
De-emphasis: OFF
Detector : (PP)/2
No audio applied to the [MIC] connector.
Transmitting
LCD display : A12 LN CTCDEV
Operating freq : 162.2750 MHz
No audio applied to the [MIC] connector.
Transmitting
Rear
panel
Rear
panel
Rear
panel
Rear
panel
Connect an RF power meter to
the [TX] antenna connector.
Connect an FM deviation meter
to the [TX] antenna connector
through the attenuator.
Connect an FM deviation meter
to the [TX] antenna connector
through the attenuator.
Connect an FM deviation meter
to the [TX] antenna connector
through the attenuator.
50.0 W
[USA2], [GEN2], [GEN4]
25.0 W
[EUR2], [FRG2]
10.0 W
[USA2], [GEN2], [GEN4]
5.0 W
[EUR2], [FRG2]
±4.4 kHz
[Other]
±3.5 kHz
[FRG2]
±4.4 kHz
[Other]
±3.5 kHz
[FRG2]
±4.4 kHz
[Other]
±3.5 kHz
[FRG2]
±0.65 kHz
[Other]
±0.52 kHz
[FRG2]
±0.35 kHz
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
UNIT LOCATION
*The output level of the standard signal generator (SSG) is indicated as the SSGs open circuit.
OUTPUT
POWER
Power (Hi)
Power (LOW)
DEVIATION
MODULATION
BALANCE
(LOW FRQ.)
(HIGH FRQ.)
CTCSS
DEVIATION
[WIDE]
[NARROW]

Other manuals for Icom IC-FR3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-FR3000 and is the answer not in the manual?

Icom IC-FR3000 Specifications

General IconGeneral
BrandIcom
ModelIC-FR3000
CategoryRepeater
LanguageEnglish

Related product manuals