INSTALLATION
Ideal Logic Heat - Installation and Servicing
“A
- See Diagram in
Frame 1
Extended centre line
155
(200)
IMPORTANT.
Ensure that, during the cutting operation, masonry falling outside of the
building does not cause damage or personal injury.
1. Cut the rear ue hole (preferably with a 5” core boring tool), ensuring
that the hole is square to the wall.
Both wall faces immediately around the cut hole should be at.
2. Drill 3 holes with a 7.5mm / 8mm masonry drill and insert the plastic
plugs, provided, for the wall mounting plate and the boiler bottom
retaining bracket.
3. Locate 2 No.14 x 50mm screws in the wall mounting plate (one at each
side, in any of the 3 holes provided at each side) and screw home.
205862-10070
X
Section
through wall
Note. Check all of the hole
positions before drilling.
Alternative
Side flue only
5" diameter hole
Turret Rear
Flue - 5” dia
Alternative
Rear Flue
5” dia
The wall mounting template is located on the internal protective
packaging. The template shows the position of the xing and rear
ue centre holes for a standard installation
Care MUST be taken to ensure the correct holes are drilled.
1. Tape template into the required position, ensuring its squareness
by hanging a plumbline as shown.
2. If tting a side ue, extend the ue centreline onto the side by
155mm on a standard wall x or 200mm if using a stand-off
bracket.
3. Mark the following on to the wall:
a The selected group of wall mounting screw holes.
b. The centre position of the ue duct. Marking both the centre
and the circumference of the ue duct.
4. Remove the template plate from the wall.
14
WALL MOUNTING TEMPLATE
15
PREPARING THE WALL
17
MOUNTING THE BOILER
(TURRET OPTION)
16
FITTING THE WALL MOUNTING PLATE
(TURRET OPTION)
Screw the wall mounting plate to the wall using 2 wall plugs
(previously tted) with the 2 screws provided.
Choose one of the 2 sets of slots in left and right bank.
Ensuring that at least one of the screws is tted into a top slot
and the mounting bracket is level.
205862-10084
Example of fixing
205862-10086
1. Remove the top ue plastic blanking disc and retain the
plastic horseshoe xing and screw.
Caution: water may discharge from open pipes
2. Lift the boiler onto the wall mounting plate (refer to the
Introduction section for safe handling advice), locating it
over the two tabs.
3. Screw the boiler bottom retaining bracket to the wall with
the screw provided.
INSTALLATION

Other manuals for IDEAL LOGIC 18

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL LOGIC 18 and is the answer not in the manual?

IDEAL LOGIC 18 Specifications

General IconGeneral
BrandIDEAL
ModelLOGIC 18
CategoryBoiler
LanguageEnglish

Related product manuals