25
INSTALLATION
Ideal Logic Heat - Installation and Servicing
FLUE OUTLET
27

1. Remove the rear ue blanking disk.
2. Lift the boiler onto the wall plate, (refer to the
introduction section for safe handling advice),
ensuring the boiler is offered to the bracket tabs at
an angle as shown below, and carefully allow the
boiler to swing down to the wall as this movement
engages the rear ue air and ue seal.
3. Screw the boiler bottom retaining bracket to the
wall with the screw provided.
4. Remove the top ue blanking disk refer to
Frame 26. Fill the condensate trap within the
boiler by pouring a cupful of water into the ue
outlet. Take care to ensure that the water is only
poured into the ue outlet, and does not spill into
the boiler casing.
5. Replace the top ue blanking disc and retain with
the horseshoe bracket and xing screw previously
removed.
During assembly check that the ue seals do not
become dislodged.
205862-10097
3
1

Other manuals for IDEAL LOGIC 18