32
INSTALLATION
Ideal Logic Heat - Installation and Servicing
36
INTERNAL INSTALLER WIRING
The Logic Heat boiler must be connected to a permanent live supply and NOT
switched by thermostats/programmers.
To install the mains cable:
1. Isolate the mains supply to the boiler.
2. Remove the front panel. Refer to Frame 13.
3. Swing the control box down into the servicing position.
4. Route incoming cable through a grommet in the bottom panel (note that the
grommets are “blind” and will require puncturing) and secure using the clamp and
screws provided in the hardware pack.
5. Connect the mains cable to the terminal block as shown.
Connecting the Switched Live to the Boiler
1. Consult the Y Plan and S Plan diagrams below.
2. Isolate the mains supply to the boiler
3. Remove the front panel. Refer to Frame 13.
4. Swing the control box down into the servicing position.
5. Route incoming cable through a grommet in the bottom panel (note that the
grommets are “blind” and will require puncturing) and secure using the clamp and
screws provided in the hardware pack.
6. Connect the switched live to the terminal block as shown.
Frost Thermostat - Wiring
If parts of the system are vulnerable to freezing or the programmer is likely to be left off
during cold weather, a frost stat should be tted in conjunction with a pipe thermostat.
LOGIC HEAT BOILER WITH Y PLAN SYSTEM
br
br
o
g/y
b
b
g/y
g
g
BOILER
LNEL
NE
LN
E
LNE
CH
ON
R/S
ON
HW
ON
HW
OFF
C/S
ON
sL
FUSED
SPUR
TIMER
CH ONLN
HW ON
HW
S PLAN
VALVE
CH
S PLAN
VALVE
R/SC/S
o
PUMP
KEY
b - blue
br - brown
g - green
g/y - green/yellow
o - orange
w - white
LOGIC HEAT BOILER WITH S PLAN SYSTEM
w
g
o
g/y
b
BOILER
L N E L N E
L N E
L N E
CH
ON
R/S
ON
HW
ON
HW
OFF
C/S
ON
sL
FUSED
SPUR
TIMER
CH ONL N
HW ON
HW OFF
Y PLAN
VALVE
PUMP
KEY
b - blue
br - brown
g - green
g/y - green/yellow
o - orange
w - white
6
INSTALLATION

Other manuals for IDEAL LOGIC 18

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL LOGIC 18 and is the answer not in the manual?

IDEAL LOGIC 18 Specifications

General IconGeneral
BrandIDEAL
ModelLOGIC 18
CategoryBoiler
LanguageEnglish

Related product manuals