43
SERVICING
Ideal Logic Heat - Installation and Servicing
53
BURNER INJECTOR REPLACEMENT
1. Refer to Frame 51.
2. Disconnect the electrical leads from
the fan.
3. Remove the clip from the gas valve
to venturi pipe and ease the pipe
upwards, rotate and ease down to
remove.
4. Loosen the screw retaining the fan
mounting bracket.
5. Lift and remove the fan and venturi
assembly.
6. Remove the 2 injector housing screws.
7. Withdraw the injector housing.
8. Fit the new injector housing complete
with injector.
9. Reassemble in reverse order, ensuring
that the new gas seal supplied is
located correctly in the injector
housing.
10. Check operation of the boiler. Refer to
Frames 40 & 41.
54
BURNER REPLACEMENT
5
5
6
1. See Frame 47.
2. Refer to Frame 51.
3. Undo the two screws and remove the sump cover.
4. Lift the manifold to clear the bottom sealing gasket and remove
manifold.
5. Remove the 2 front xing screws and loosen the 2 rear extended
nuts.
6. Lift off the burner from the combustion chamber. To facilitate the
removal angle the burner as shown.
7. Fit the new burner, replacing any damaged or deteriorating sealing
gasket.
8. Reassemble in reverse order. Refer to Frame 50.
9. Check the operation of the boiler. Refer to Frames 40 & 41.
3
3
4
2
4
3
6
Injector
SERVICING

Other manuals for IDEAL LOGIC 18

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL LOGIC 18 and is the answer not in the manual?

IDEAL LOGIC 18 Specifications

General IconGeneral
BrandIDEAL
ModelLOGIC 18
CategoryBoiler
LanguageEnglish

Related product manuals