38
Revision History
Revision Date Revising Author Description
0.0 25
th
MAR4 Xiong Fei Related firmware version: F7-10=312.00 and F7-11=312.02
0.1 17
th
APR4 Xiong Fei 1. Related firmware version: F7-10=312.01 and F7-11=312.04.
2. Add mounting hole dimensions into General specifications;
3. Revise Connection diagram;
4. Add motor thermal protection function codes and some others in
to function
parameters;
5. Correct some items in Elevator quick commissioning;
6. Add motor auto-tuning steps into Elevator quick commissioning.
0.2 18
th
JUN2014 Xiong Fei 1. Related firmware version: F7-10=312.01 and F7-11=312.05.
2. Add nameplate and designation rule;
3. Add MD38IO1 into wiring diagram;
4. Add operation panel into quick setup;
5. Improve setup flowchart;
6. Improve trouble shooting;
7. Add extension cards;
0.3 08
th
JUL 2014 Xiong Fei & Subra
& Arut
1. Related firmware version: F7-10=312.01 and F7-11=312.05;
2. Simplify wiring diagram, remove Elevator controller block;
3. Add IGBT Enable function into Chapter 3;
4. MD38IO1 shows as pre-fitted extension I/O card.
0.4 15
th
JAN Xiong Fei 1. Related firmware version: F7-10=312.03 and F7-11=312.06;
2. Revise the ratings of recommended braking resistors;
3. Add current loop gain parameters (F2-13 to 16);
4. Add overcurrent stall prevention parameters (F3-19 to 20);
5. Add software temporary version parameters (F7-15 to 16);
6. Add factory parameters (FF-00 to 03);
7. Revise protection parameters F9-03, F9-04, F9-07 and F9-13;
8. Add fault code Err61 (Two or three drive output phases loss);
9. Revise the name of Err13(One drive output phase loss);
10. Revise braking operation level from 770VDC to 750VDC;
11. Revise DC injection active time range F6-06 and F6-14;
12. Revise S curve time proportion range F6-08, 09, 26, and 27;
13. Revise default values of F8-55, 56, 57;
14. Revise wiring diagram, move MC and Brake to TA/TB/TC and PA/PB/PC;
15. Revise auto-tuning methods F1-37;
16. Revise F5-01, F5-02, F5-03, F5-04, re-arrange digital outputs;
17. Revise IGBT enable description(DO active mode setting);
0.5 8
th
JUL Xiong Fei 1. Related firmware version: F7-11=312.07;
2. Revise description of IGBT Enable;
3. Add F3-22 to 25, F9-08, FP-03
4. Change F0-15, F3-23, F6-05, F6-13
5. Revise wiring diagram, add phase monitor relay and MC relay to DI6;
6. Adjust the chapter sequence;
7. Add DI7 as multi-reference in wiring diagram;