Intel® Server Board S2600CO Family TPS Appendix G: Post Code Errors
Revision 1.4
Intel order number G42278-004
151
Table 81. Integrated BMC Beep Codes
Code Reason for Beep Associated Sensors
1-5-2-1 CPU socket population error CPU1 socket is empty, or sockets are populated
incorrectly
CPU1 must be populated before CPU2.
1-5-2-4 MSID Mismatch MSID mismatch occurs if a processor is installed
into a system board that has incompatible power
capabilities.
1-5-4-2 Power fault DC power unexpectedly lost (power good dropout)
– Power unit sensors report power unit failure
offset
1-5-4-4 Power control fault Power good assertion timeout – Power unit
sensors report soft power control failure offset
1-5-1-2 VR Watchdog Timer VR controller DC power on sequence was not
completed in time.
1-5-1-4 Power Supply Status The system does not power on or unexpectedly
powers off and a Power Supply Unit (PSU) is
present that is an incompatible model with one or
more other PSUs in the system.