Intergas Heating Ltd 32
9.5 Shutting down
CAUTION
Drain the appliance and the installation if mains power has
been interrupted and there is a possibility of freezing.
1. Adjust all valves to manual operation.
2. Drain the appliance at the drain tap.
3. Drain the installation at the lowest point.
9.5.1 Frost protection
To avoid freezing of the condensate drain pipe the appliance must be installed in a
frost-free area.
To avoid freezing of the appliance it is equipped with frost protection. If the
temperature of the heat exchanger becomes too low, the burner switches on until the
temperature of the heat exchanger is sufficient. If there is a possibility of the
installation (or part of it) freezing, an (external) frost thermostat must be installed at
the coldest point of the return pipe. This must be connected in accordance with the
wiring diagram (See chapter 13).
NOTE
If an (external) frost thermostat has been fittted to the
installation and connected to the appliance, this will not be
active when the appliance is switched off at the operating panel
(
-
--
-
on service display).

Table of Contents

Other manuals for Intergas Compact HRE 18 SB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intergas Compact HRE 18 SB and is the answer not in the manual?

Intergas Compact HRE 18 SB Specifications

General IconGeneral
BrandIntergas
ModelCompact HRE 18 SB
CategoryWater Heater
LanguageEnglish