Function and Features
Copyright© Itech Electronics Co., Ltd. 30
Wiring instruction:
1. Connect the external load’s connection terminal of IT6500C Series power
supply to the load input interface of IT-E500 Series power dissipater.
Connections of other power dissipaters are as shown in blue lines in the
figure.
2. Connect the external load AC input interface OUTPUT (LOAD) of IT6500C
Series power supply to the AC input interface of the power dissipater. AC
input connections of other power dissipaters are as shown in red lines in
the figure. Please pay attention to corresponding L/N/G terminals.
Set load input
When using load function, the user can set load current, power and slope as
well as OCP, OPP, etc.
Set the load input current and input power in Setup menu. Details about load
input current/power are as shown below.
In internal load mode, the value of load power is defaulted to rated value, and
the value of current is defaulted to a small value. In external load mode, the
values of load power and current are defaulted to zero.
1. Press [Shift]+ [V-set](Setup) to enter the Menu operation. The interface
displays information as follows: