Functions and Characteristics
Copyright © Itech Electronic Co., Ltd. 41
VON LATCH MODE
In Latch mode, as before, the load will turn on only when the voltage
exceeds VON setting, but once on, it will now stay on, even if the voltage
drops to zero.
3.13 Protection Function
IT8500+ series electronic load supports the following protection function:
Over voltage protection (OVP)
Over current protection (OCP)
Over power protection (OPP)
Over temperature protection (OTP)