FOR THE INSTALLER
Warning
The installer and service menu (I/S) is
only for installers. Under no circum-
stances may the user access this level.
(10 sec)
As the installer you have your own section of menus for settings, e.g. for
commissioning. These are accessed from the control panel by holding
down the menu button for approximately ten seconds.
The menu displays are divided into lines and each display has a number to
make it easy to fi nd. If there is no activity for 30 minutes the menu display
automatically returns to customer level 1.
The installer level also includes Customer levels 1 and 2.
How to use the control panel
Here follows an example of how to use the control panel. The example
shows how you move to menu display 5.13 and confi rm the external
sensors. You will also fi nd more information about the control panel under
the heading Control Panelin the User section.
1. Press the menu button for approximately ten seconds until Access =
SERVICE is shown on the menu display. Now press the Menu button.
2. The menu display Indoor temperature settings(menu 1) is shown.
3. Turn the menu dial clockwise (to the right) until you access the menu
Commiss./Service for installer(menu 5). Now press the Select button.
4. Turn the menu dial clockwise until you reach the menu Connected extra
sensor in op. (menu 5.13). Now press the Select button.
5. The display window Extra sensor is shown. Confi rm the extra sensors
that you have connected by pressing the Confi rm button.
6. The text Confi rmingis briefl y shown in the menu display. This means
your setting is being registered in the heat pump.
7. When the setting has been registered the previous menu display is
shown. Press the Return button twice to return to the main menu.
Commissioning the heat pump
Installer and service menu (I/S)
Rego 637 I/S
080922 16:08:15 Tu
Heat Info Menu
Main menu
Indoor temperature
settings 1
Return Select
Main menu
Commiss./Service
for installer 5
Return Select
Commiss./Service
Connected extra
sensor in op 5.13
Return Select
Extra sensor(s)
GT4 GT5
Return Confi rm
Extra sensor(s)
Confi rming…
Extra sensor(s)
GT4 GT5
Return Confi rm