36
ted in one of these modes:
- “auto” (operation on demand);
- “economy” (operation during the night);
- “day” (operation only during the day).
To go back to the Home menu, close the Monitor menu.
• access the Manage menu
this menu lets you, among other things, activate a “fun-
ctions-lock”, if you want to prevent some parameters of the
hot tub (including the temperature) from being changed by
unauthorised people. When required, enter a lock/release
code (be sure to save it).
Through this menu you can also check the strength of the
network signal, change the unit of measurement of the
temperature, and access publications regarding the care and
maintenance of the hot tub.
What’s more, you can check (and, if you want, clear) the
reminders about:
- replacing the Clearray® bulb;
- changing the water;
- replacing the filter cartridges;
Please see the manual for further details about these opera-
tions.
QOperation indicators on the SmartTub™ controller
The SmartTub™ controller (located on the edge of the tub, in the
technical unit) is equipped with LED lights which indicate the
operational status of the appliance:
- Cloud LED (blue)
on: connected to network / off: not connected to network.
- Hot tub LED (blue)
on: connected to hot tub / off: not connected to hot tub.
- Status LED
pale blue light that flashes slowly: network connection status OK
pale blue light that flashes rapidly: status of connection to network
in progress.
flashing green light: awaiting connection to network.
flashing blue light: SIM card error.
- Cellular signal LEDs (blue)
indicate strength of signal.
Reinitialising the controller
If you have to restore the appliance to factory settings, position
magnet A alongside the “reset” label (see photo).
A
A
Menu Features and Programming Instructions
Your spa is equipped with menus that allow you to program addi-
tional features. By continually pressing the Menu ( ),button you
will cycle through the menus as follows:
Current temperature (Main Menu)
External lights
Primary Filtration
Secondary Filtration
Heat
Filter Change
UV
H2O
Time
Date
Temp
Language
Lock
WiFi (not available)
S\N
Primary Filtration Menu
During the primary ltration cycle, the circulation pump and
CLEARRAY are activated. The spa is programmed with a default
setting starting at 12:00 AM and lasting for 8 hours, but this can
be changed. This cycle allows the circulation pump to run for a
preset amount of time per day, in addition to the normal oper-
ation.
Note: Any time the circulation pump runs outside of a program
cycle, e.g. for heating, that run time will be deducted from the
next primary lter cycle. For example, the primary lter cycle is
set to 8 hours every 24 hours but the circulation pump comes on
for 2 hours to heat the water after the cycle has nished. The next
primary lter cycle will only be for 6 hours not 8 hours.
Programming the Primary Filtration Cycle
To change the programmed Primary Filtration Cycle:
1. Press ( ) until you see the menu “PF”. The text “PRIMARY
FILTER” (primary ltration cycle) scrolls across the screen.
2. Press or to display the current start time and prepare the
system for changes.
3. Press or to adjust the start time, in 1-hour increments. To
switch from “AM” to “PM” you must round a 12-hour period.
4. Press (
) to conrm and save the start time.
5. Press
or to adjust the duration of cycle, in 1-hour incre-
ments.