B. Resetting the duration countdown timer (CLEARRAY System only)
Once the duration countdown timer for the CLEARRAY System has reached zero, you will need to reset it,
replace the UV bulb and clean the quartz tube.
To reset the duration countdown timer:
1. Press and hold the Jets pump 1 (
) and Cooler ( ) button at the same time for 3 seconds.
2. Press the Warmer (
) button until the display shows “0.”
3. If the timer has reached “0,” pressing the Jets pump 1 (
) button will reset it. If the timer is not at “0”
pressing the Jets pump 1 button will not reset it.
Note: If the spa power is interrupted, the duration countdown timer is not affected. The number of days remain-
ing is stored in the memory and will continue to countdown once power is regained.
4. If the duration countdown timer is not at “0” and you need to reset it:
a. Press and hold the Jets pump 1 and Cooler buttons at the same time for 3 seconds.
b. Press the Warmer button to scroll to “U.”
c. Press the Jets pump 1 button to switch from “U” to “O3.”
d. Press and hold the Jets pump 1 and Cooler buttons at the same time for 3 seconds.
e. Press the Warmer button to scroll to “O3.”
f. Press the Jets pump 1 button to switch from “O3” to “U.” The timer has been reset to 365 days.
4.9 2011 Aftermarket Ozonator Facts
Ozone System Specications are:
J-LX Ozone System Specications
• Circulation pump and ozone run 8 hours. Cycle starts approximately two minutes after power up.
• Ozonator shuts off when either JETS button is pressed. The Ozonator will resume operation approximately
5 minutes after jets are turned off intentionally or automatically. The ozonator also shuts off if the hot tub
goes into “summer logic.” See Section 5.4 (page 14).
• Pressing a JETS button during an active lter cycle cancels the lter cycle until the next term.
Note: Pump may stay on if a heat call is present.
J300 Ozone System Specications (All 2011-2013 models)
J200 Ozone System Specications (J-270, J-280, and J-230 models with a Circulation Pump)
• Circulation pump and ozone run 24 hrs.
• Ozonator shuts off when either JETS button is pressed. The Ozonator will resume operation approximately
5 minutes after jets are turned off intentionally or automatically. The ozonator also shuts if the hot tub goes
into “summer logic.” See Section 5.4 (page 14).
• Pressing a JETS button during an active lter cycle cancels the lter cycle until the next term.
Note: Pump may stay on if a heat call is present.
J200 Ozone System Specications (Models without Circulation Pump)
• Ozonator runs during a programmed lter cycle.
• Ozonator turns off when either JETS button is pressed and will resume operation approximately 5 minutes
after jets are turned off intentionally or automatically.
• Pressing a JETS button during an active lter cycle cancels the lter cycle until the next term.
Note: Pump may stay on if a heat call is present.
Press Press
1