EasyManuals Logo
Home>Jacuzzi>Hot Tub>LED Series

Jacuzzi LED Series User Manual

Jacuzzi LED Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
38
8.10 Weak or Surging Jets
Weak or surging jets are usually caused by an insufcient water supply to the pump or a
clogged or broken pump impeller. The water level may simply be low, or there may be an ob-
struction in the water ow path to the pump or in the pump’s impeller. Before making a service
call, ask customer to verify all jets are open.
Suggested Spare Parts: Filter cartridge, Pump
Standard Troubleshooting Approach
Is the water level
OK?
Is the lter cartridge
clogged or dirty?
Is the lter cartridge
installed correctly?
Is the weir gate or
skimmer operating
correctly?
Clean or replace lter
cartridge.
Take pump housing
apart. Is debris
present in pump
impeller? Is the
impeller broken?
If pump suction line
is clear, check for
blockage in plumbing
on the return side
of pump. Call
Technical Support
for assistance in
performing this
verication step.
Remove debris
or replace broken
impeller and retest
system.
Fix lter installation
problem.
Adjust the water level
and retest.
Is there debris or a
loose foreign object
between the lter and
pump input?
Remove debris or
loose foreign object.
No
Yes
Yes
No
No
No No
Yes
Yes Yes

Table of Contents

Other manuals for Jacuzzi LED Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jacuzzi LED Series and is the answer not in the manual?

Jacuzzi LED Series Specifications

General IconGeneral
BrandJacuzzi
ModelLED Series
CategoryHot Tub
LanguageEnglish

Related product manuals