Page 7
ENGLISH
Jandy
®
AquaLink
®
TCX™ Power Center
|
Installation & Operation Manual
Jandy
®
AquaLink
®
TCX™ Power Center
|
Installation & Operation Manual
1.4 Materials Supplied by the Installer
• Flexible Conduit
• Conduit Connectors
• Wire High Voltage #12 AWG Minimum
• Wire Low Voltage - 4 conductor
Min. #22 AWG Communication Cable
(Insulation Colors: Red, Black, Yellow, Green)
• Wire Connectors (wire nuts)
• High Voltage Breakers
• GFCI Receptacle or GFCI Breaker
1.5 Specications
Power Supply
USA
240/120VAC; 60/50 Hz; 0.5 A
CAN
240/120VAC; 60/50 Hz; 0.5 A
Contact Rating
USA
High Voltage
25 A; 3HP @ 240VAC
1 1/2 HP @ 120VAC
1500 Watts Incandescent
Low Voltage Class 2, 1 A @ 24VAC
CAN
High Voltage
25 A; 3HP @ 240VAC
1 1/2 HP @ 120VAC
1500 Watts Incandescent
Low Voltage Class 2, 1 A @ 24VAC
WARNING
The AquaLink TCX power center should not be considered
suitable for use as service equipment. Therefore, it is
required to have the appropriate means of disconnection,
circuit isolation, and/or branch circuit protection installed
upstream of the power center.
Section 2. System Overview
This manual provides installation and basic operational
instructions for the Jandy AquaLink TCX power center.
The AquaLink TCX is an integrated automation system
capable of controlling and scheduling a wide array of
equipment for residential pools.
Read the installation and operation instructions
completely before proceeding with the installation.
Keep this manual in a safe place for future reference
when inspecting or servicing the power center.
Before starting, check that you have the correct parts as
indicated below. If any parts are missing or incorrect,
please call your local distributor or technical support at
1-800-822-7933 for assistance.
2.1 Package Contents
Package contents will vary depending on which AquaLink
TCX conguration you are installing.
AquaLink TCX Pool Only W/Automation
Enclosure* and PIB
Mounting Hardware
• Screw #8-15 X 1 1/4” (Qty 3)
• Wall Anchor #8 1” (Qty 3)
Screw And Fuse Goody Bag
• Fuse 5A/125V
• O-Ring 5/32” ID
• Screw #8-32 X 3/8”
Wire Cover Tube Kit
• 24” Tubing
• Bushing 20.4mm
• Bonding Lug
• Screw #10-24 X 5/8”
• Nut 10-24
Air Temperautre Sensor
Wireless Light Switch/Wallplate
Command Hub
*Note: Enclosure only included on TCXP model.
Conversion Kit model does not include enclosure.
2.2 Location Requirements
In order to protect the AquaLink TCX power center from
pressurized water spray (such as that from irrigation
sprinklers) and from mechanical impacts and/or damage,
it should be located:
• Near the primary equipment pad.
• At least 2′ (61 cm) above the ground.
• At least 5′ (1.5 m) away from the inside edge of the
pool or spa in the US.
• At least 3 m (9.8′) away from the inside edge of the
pool or spa in Canada.
Section 3. AquaLink TCX Power
Center Installation
3.1 Mounting
The AquaLink TCX power center is shipped with
mounting brackets fastened on the back.
• Turn the power center over and inspect the brackets
installed on the back.
• If any parts are missing or damaged, please call
your local distributor or technical support at
1-800-822-7933 for assistance.