(Take Position as Sector Offset)
Is taking current actual position as an offset for all
sectors with restart of monitoring.
Furthermore the positions Wait for distance
greater/less“ and „Jump if distance greater/lessare
adjusted by this offset.
TPSO
(typically touching position , also refer
to chapter 13.2.3 Sector Offset for
Touching Position)
Provide offset for all sectors with restart of
monitoring.
xx = [Inc] offset
Furthermore the positions Wait for distance
greater/less“ and „Jump if distance greater/lessare
adjusted by this offset xx.
E.g. xx = 0, sets offset to 0