35
10.2 Quick Start (only with LINAX® and ELAX®
linear motor axes)
The Quick Start function allows the user to setup the
LINAX® or ELAX® linear motor axis with the XENAX®
controller simply immediately after receipt of the
components.
It is completed per mouse click, without parameter
settings and without an instruction manual.
By pressing the Quick Start button, a system check is
automatically started including the following tests:
Cable connections, power voltage, input functions,
functionality of the measuring system, parameter settings
and current flow of the linear motor.
In order to test the functionality of the measuring systems
the system asks you to move the slider of the LINAX® linear
motor axis of a distance of at least 20mm back and forth.
With the START the LINAX® or ELAX®
linear motor will be
referenced automatically and will then move the distance
back and forth that was indicated manually by hand
before.
For the Quick Start Function it is recommended to operate
the linear motor axis in horizontal orientation without a
payload.
The dynamics can dynamics be adjusted with the slider
“DYNAMIC”.