KE2000 Installation Manual
45
16-2. Adding the trolley spacers (For height adjustment)
If the overall feeder exchange trolley does not enter the main unit due to inclined machine
installation place (floor level of the machine installation factory) or low overall feeder
exchange trolley height, it is necessary to adjust the height of the overall feeder exchange
trolley by adding the trolley spacers (E2738721000).
<Procedure>
1. Loosen the fixing screws.
2. Insert the M6 screw into the height
adjustment tap. Turn the screw to
make the gap between the caster
plate and trolley frame until the
trolley spacers can be inserted into
it.
3. Insert the required pieces of the
trolley spacer into the gap.
4. Remove the adjustment screw and
tighten the fixing screws
16-3. Adjusting the bank stopper mounting position
The bank stopper position is adjusted in three steps (upper, middle, lower) based on the
board transport height. (See Table 16-3-1 below.)
Table 16-3-1
Board transport height Bank stopper mounting
position
894900
914920
Lower
887893
907913
Middle
880886
900906
Upper
Unit:mm
<CAUTION>
For overseas models, 50 mm is added to the above height.
Fig 16-2-1
Fig
16-3-1
Trolle
y
s
p
acer
Roller guide
Bank stopper

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JUKI KE-2000 Series and is the answer not in the manual?

JUKI KE-2000 Series Specifications

General IconGeneral
BrandJUKI
ModelKE-2000 Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals