Page #36 background imageLoading...
Page #36 background image
- 3
-
2. X-Y Unit
(1) Fixing the Y-axis Rail (Fixing the X-axis Frame Assembly)
q Move the whole X-axis frame completely to the front of the machine, then push it
against the stopper rubber located on the front side.
w Fix the safety cover stoppers (E1348700000) on two taps (right and left) located
on the linear guide of the Y-axis frame with the M5 x 20 screws from the rear side.
Adjust the eccentricity of the stopper to push the Y-axis frame against the rubber
on the front, then fix it.
e Attach the set-up caution tag onto the fixing part.
Figure 2.1
M5 x 20 screw
(SM6052002TN)
Set-up caution tag
X-axis Unit
Tap E1348700000