37
6-4. How to use the temporary stop
Once the RESET key function is set to the "pause" by means of the memory switch U031, the RESET key
will function as the pause key to allow the sewing machine to be stopped during sewing. (Refer to
"I.8-2. List
of the memory switch functions" p.59
.)
1) The sewing machine is stopped by pressing RE-
SET key
󱀁
.
When you press RESET key
󱀁
, the
error is reset and the thread trimming screen is
displayed. When press RESET key
󱀁
again, the thread trimmer operates to trim the
thread and the feed forward / backward screen is
displayed.
2) Three operations can be carried out after the
error is reset.
1. Re-starting of sewing with the start switch
2. Adjust the positioning with DATA CHANGE key
󱀅
. Press the START switch to re-start
the sewing machine.
3.
Press RESET key
󱀁
to return the sewing
machine to the origin.
󱀅
󱀁
󱀁