102
3Clear screen is displayed.
After inputting the setting time, determine the time with 1.
■Warning time input screen
4
1
2
3
2) Press 2 to display the maintenance function screen. (For other functions, refer to the Engineer's Manual.)
■Maintenance function screen
2
3
5
4
34and 5 : Warning time input screen is displayed.
3) Set the warning time with 2. Setting time inputted is shown in reverse video at 4.
■Sewing management information selection screen
In case of stopping the warning function, set the set value to “0”.
It is possible to individually set replacement of needle, cleaning, and replacement of oil
respectively. In case of stopping all, set “0” to each.
Impor tant
Initial value of warning setting time
1 Time of replacement of needle : 1,600 thousand stitches (kn)
2 Time of cleaning : 16 hours (h) (Current carrying time)
3 Time of replacement of oil : 120 hours (h) (Availability time)
Reference