Mounting and installation User Manual B-Net 93 60
38 © Kaba Benzing GmbH 01/2006
5.6.12 SV9001 power supply
The terminal may be equipped with the internal power supply SV9001.
+ -
I 0
NL1
24 V DC
12 V DC
6 V DC
1
2
3
4
5
Fig. 24: SV9001 power supply
1 Jumper to set door-opener voltage
2 24 V AC operating voltage for the terminal
3 Operating voltage for door-opener
24 V DC, 12 V DC or 6 V DC; depending on jumper position
max. 4 VA 100% on-time, max. 8 VA 10% on-time
4 Power input 115 V AC max. 140 mA (115 V version)
Power input 230 V AC max. 70 mA (230 V version)
5 Mains switch
NOTICE!
With the terminal’s 24 V AC operating voltage (terminal 2), NO additional door-
opener may be supplied.