User manual wM-Bus Dongle SW Tool
Appendix A: DSMR set-up
5512-1057 GB / 12.2011 / A1
Figure 8
Set-up of a DSMR meter:
After starting the meter, find the meter in the Main tab, and transfer the data to the wanted
Meter X tab, or enter the meter data manually.
Set the OPTIONS to 0x07 0x0F, depending on whether the wired M-BUS should be encrypted or
not.
Set Meter install state to 255. Next time the meter sends out an ACCESS DEMAND INSTALL STATE
(CI=0x06), the Dongle will acknowledge this, and the state will change to 1 when seeing the
next message from the meter.
Set Meter M-Bus address to where you want the meter to respond on the M-Bus.
Rev B barcode is not used.
11