User manual wM-Bus Dongle SW Tool
Appendix E: OMS T2 meter set-up
5512-1057 GB / 12.2011 / A1
Figure 13
If the option board (radio module) in the meter is an OMS T2 type, the set-up should be as follows:
Transfer the data from the Main tab, or enter the METER ADDRESS manually.
Set the options as shown, i.e. tick the checkboxes Meter enabled, 2-way radio, OMS T2 protocol
and Meter data valid (Options in hex = 4B).
Set Meter install state to 1 as there is no installation procedure.
Set T1 period (in seconds) to how often the meter is to send out meter data. T2 fraction is not
used.
Enter the same key in IEK and KEY.
Rev B barcode is not used.
For the Option Board data fields, see 3.2 Meter x tabs.
No Encryption on M-Bus:
Tick this checkbox if the decryption has to be done in the back office (then the Options in HEX
will show 43).
Important for OMS: Both IEK and KEY must be set, and set to the same key.