37
GB
Operation of the Unit
1) good - speed remains stable at increasing torque
2) bad - speed decreases with increasing torque
3) bad - speed is increased too much at load
=
=
=
=
n
real
f
n
real
f
n
real
f
n
real
f
CP.18
OK !
CP.19
CP.18
CP.19
load
f/n
real
M
n
1
23
Slip compensation
Slip compensation balances the speed changes caused by the load
variation. In order to activate the function, set the value at 1.00 and
optimize as directed in the examples below.
Adjustment range: -2.50...2.50
Resolution: 0.01
Factory setting: 0.00 (=off)
Customer adjustment: _______
Autoboost causes an automatic I*R-compensation by raising the output
voltage during high load torques. The magnetizing current remains
constant. To activate the function set the value to 1.00 and optimize as
directed in the examples below. Check the motor voltage to see, whether
it returned to the normal value after no load of the drive. Otherwise reduce
CP.19.
Adjustment range: -2.50...2.50
Resolution: 0.01
Factory setting: 0.00 (=off)
Customer adjustment: _______
Slip compensation and autoboost work on the basis of presetting
motor data. When using a special motor or in case of
overdimensioning of more than one size, then both functions
should be deactivated.
Autoboost
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Other manuals for KEB COMBIVERT F4-C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F4-C and is the answer not in the manual?

KEB COMBIVERT F4-C Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F4-C
CategoryDC Drives
LanguageEnglish

Related product manuals