Terminal Description
X2.5
Control Mode
In activating the input you can switch from open loop operation to speed
controlled operation.
! only when LF.30 = 1 !
X2.6
Door Drive
In addition to the main drive the inverter can also start a door drive. The
Active
activation of the input causes the switching from the main drive to door
drive. For settings, functions and drive curves of the door drive
see pages GB 14 - GB 15 !
X2.7
Door Drive
When the input is set with +24 V the set value of the door drive is activated.
Setpoint Input
The set speed of the door drive is preset in parameter LF.46. For
settings, functions and drive curves of the door drive see page
GB 14 - GB 15 !
X3.1
Contactor Control
The input X3.1 checks to see if the main contactor and the braking
contactor are released. The input must be activated when a drive
command is entered. If the input is not set, the display “S.Co” (Error,
contactor open) appears in parameter LF.98. The power modules are
blocked.
The contactor control can be simulated, by bridging input X3.1 with
output X2.9.
X3.2
Correction
When the input is assigned +24 V the correction speed is activated.
Speed
V
B
! also see parameter LF.40 !
X3.3
Crawl Speed,
V
E
When the input is assigned +24 V the crawl speed is activated.
! also see parameter LF.41 !
X3.4
Rated Speed,
V
N
When the input is assigned +24 V the rated speed is activated.
! also see parameter LF.42 !
X3.5
Inspection Speed,
When the input is assigned +24 V the inspection speed is activated.
V
I
! also see parameter LF.43 !
X3.6
1st Intermediate
When the input is assigned +24 V the 1st intermediate speed is activated.
Speed,
V
1
! also see parameter LF.44 !
X3.7
2nd Intermediate
When the input is assigned +24 V the 2nd intermediate speed is activated.
Speed,
V
2
! also see parameter LF.45 !
Motor Temperature De-
Terminal motor-PTC !
tector Terminals OH/OH
see also page GB 11, terminal X3.23
3. Inputs/Outputs

Other manuals for KEB COMBIVERT F4-F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F4-F and is the answer not in the manual?

KEB COMBIVERT F4-F Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F4-F
CategoryLifting Systems
LanguageEnglish