SECTION
3
Maintenance
Volts
Rangmg
Table
35
hsts
the
switches
that
are
closed
for each of
the
available
voltage
ranges.
This
table
applies
to
both
source
and measure
voltage
ranges.
Table
35,
Analog
Switching;
Volts
Ranging
K15
and
K5
wffl
dose
whenever
the
instrument
is
placed
in
standby.
Table
34,
Analog
Switching
Sensing
Relays
Range
Closed
FET
Switches
Closed
L1V
K4,
K6,
K7
Q24, Q33, Q35
liv
K4, K6,
K7
Q24
110V
K7
1100V
Feedback
As
listed
in
Table
3-6,
analog
switches
U48
and
U49
are
used
for
feedback
switching.
Each of
these
two
devices
has
four
individual
switches
and
are
identi
fied
by
their
circuit
schematic
pin
numbers.
The
table
lists
the
states
of
these
switches
for
standby
and
operate
con
ditions
while
programmed
to
source
current
and
voltage.
Sensing
As
listed
in
Table
37,
three
relays are
used
to
select
local
or
remote
sensing.
Note
that
when
the
instru
ment
is
programmed
for
remote
sensing,
the relay
switches
wffl
default
to
the
local
sensing
states
when
placed
in
standby. That
is,
relay
K3
will
open,
and
relays
_______
Relays*
Sense
K3
K15
K5
Local
Open
Closed
Closed
Remote
Closed
*Relay
states
with
236/237
in
OPERATE.
In
standby,
relays
go
to
local
sense states.
Output
For
safety,
there
are
two
relays
that
are
used
to
disconnect
OUTPUT
HI
and
SENSE
HI
from
the
rear
panel
output
triax
connectors.
When
the
instrument
is
off,
relays
Kl
and
K2
are
open.
When
turned
on,
these
re
lay
switches
remain
open
until
the
instrument
is
first
placed in
operate.
These
two
switches
then
remain
closed
while the
instrument
is
powered
on.
A/D
Multiplexing
During
normal
operation, the
A/D
multiplexer
(Ui)
continuously
applies
a
sequence
of
sig
nals
to
the
input
of
the
A/D
converter.
These
signals
in-
clude
Zero,
Reference
and
Measure
(1
or
V).
Only
one
sig
nal
is
switched
to
the
A/D
input
at
one
time. The
switch
ing
speed
and
sequence
varies
according
to
how
the
in-
strument
is
programmed
to
operate.
In
the
A/D
test
mode
(see
paragraph
3.8.2)
the
A/D
con
verter
is
locked
up
in
the
desired
A/D
phase.
This
allows
Table
3-6,
Analog
Switching;
Feedback
Switches
Source
1
Measure
V
Source
V
Measure
1
Device
Pins
Standby
Operate
Standby
Operate
U48
6,
7
Closed
Open
Closed
Closed
U49
6,7
Closed
Open
Closed
Closed
U48
2,
3
Closed
Open
Closed
Closed
U49
10,
11
Closed
Open
Closed
Closed
U48
10,
11
Open
Closed
Open
Open
U49
14,
15
Open
Closed
Open
Open
U48
14,
15
Open
Closed
Open
Open
2,
3
=
Closed
3-15

Table of Contents

Other manuals for Keithley 236

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 236 and is the answer not in the manual?

Keithley 236 Specifications

General IconGeneral
BrandKeithley
Model236
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals