PARAMETS DESCRIPTION DEFAULT MIN MAX UNIT
1
SP.h.
Use of PHOTO1 when starting from closed
0 = PHOTO1 is checked
1 = The gate starts even with PHOTO1 excited
1 0 1
2
Ph.2.
Use of PHOTO2
0 = Enabled during both opening and closing AP/CH
1 =Only enabled during opening AP
0 0 1
3
tP.h.
Photo-device test
0 = off
1 = PHOTO1 on
2 = PHOTO2 on
3 = PHOTO1 and PHOTO2 on
0 0 3
4
Ed.m.
STOP/EDGE input selection
0 = STOP contact (NC)
1 = Resistive safety edge (8k2)
2 = Contact safety edge (NC)
0 0 2
5
iE.D.
Sensitive edge tripping mode
0= only tripped during closure with direction reversal
1 = stops the automation (during both opening and closure) and
retreats from the obstacle
0 0 1
6
tE.D.
Edge test
0 = off
1 = on
0 0 1
7
LP.o.
Pedestrian opening 50 0 100 %
8
TP.C.
Time for automatic closure from pedestrian opening (0=off) 0 0 900 s
9
FP.r.
Flashing light output setup
0 = Steady
1 = Flashing
1 0 1
10
tP.r.
Pre-ashing time (0 = off) 0 0 20 s
11
FC.Y.
Courtesy light setup
0 = On at end of operation for time TCY
1 = On if gate not closed + duration of TCY
2 = On if courtesy light timer (TCY) time not out
0 0 2
12
tC.Y.
Courtesy light on time 0 0 900 s
13
de.a.
Hold-to-run
0 = off
1 = on
0 0 1
14
IN.D.
0 = deactivated
1 = gate open light ON/OFF
2 = gate open light proportional
- Slow ashing with gate opening
- Quick ashing with gate closing
- Steady light if gate open
- 2 ashes + pause with gate stationary (position other than closed)
3 = Electric lock
4 = Magnetic electric lock function with output active when gate/door
is closed
N.B. interface with an external relay with 24 Vdc winding. To activate
this function, the pre-ash must be enabled at the recommended
value of 1 sec (tP.r. ≠ 0)
0 0 4
The ADVANCED MENU allows the system to be further customised
by modifying parameters not accessible from the basic menu.
To access the ADVANCED menu, press the MENU key and hold it
down for 5 seconds.
To modify ADVANCED MENU parameters, proceed as described
for the BASIC MENU.
N.B. Some default functions/display items may vary with respect to
the type of motor selected.