3.10.1 Belt Tensioning Procedure
1. Check the seawater pump belt deflection (tension) here
2. Seawater pump pulley
3. Belt guard
4. Wing screw and belt guard mounting hardware (qty. 3)
5. Engine mounting brackets (qty. 3)
6. Pivot screw (underneath pulley in slotted hole)
7. Seawater pump adjusting screw
Figure 47 Seawater Belt Tension (14-24EKOZD/12-20.5EFKOZD Model Shown)