EasyManuals Logo
Home>Kohler>Portable Generator>14EKOZD

Kohler 14EKOZD User Manual

Kohler 14EKOZD
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #92 background imageLoading...
Page #92 background image
92 TP-7044 6/23
11. Check that the generator set is OFF.
12. Reconnect the generator set engine starting battery, negative (-) lead last.
13. Reconnect the power to the battery charger, if equipped.
3.11 Battery
Consult the battery manufacturer’s instructions regarding battery care and maintenance.
3.12 Generator Storage Procedure
Keep the craft afloat for generator operation during the storage procedure. Follow the procedure below when storing your
generator set for 3 months or more.
Generator Set Storage Procedure
1. Start and run the generator set until it reaches operating temperature or about 15 minutes.
2. Stop the generator set.
3. Change the oil and oil filter. See the Oil Change section.
4. Close the seacock and remove the hose at the seacock. Place the hose in a container having approximately 3.7-7.5 L
(1-2 U.S. gallons) of coolant/antifreeze. Kohler Co. recommends using an environmentally friendly potable antifreeze
such as Peak
®
RV/marine propylene glycol/water mix or equivalent.
5. Disconnect the lead (#87) to the low seawater pressure (LWP) switch.
6. With a suitable container at the exhaust outlet, run the generator set until coolant discharges at the exhaust outlet or
until the coolant mixture is depleted. Do not allow coolant mixture to flow into waterways.
7. Reconnect the lead (#87) to the low seawater pressure (LWP) switch.
8. Stop the generator set.
9. Connect a hose to the seacock. Leave the seacock closed.
10. Check the coolant level of the heat exchanger and add coolant if necessary.
Note:
Use antifreeze capable of withstanding the lowest possible temperatures.
11. Clean the exterior of the generator set and spread a light film of oil or silicon spray over any exposed surfaces that may
be subject to rust or corrosion.
12. Disconnect and remove the battery. Place the battery in a warm, dry location for the storage period. Recharge the
battery once a month to maintain a full charge.
13. Select a well-ventilated (not humid or dusty) location to store the generator.
14. Cover the entire unit with a dust cover.
Note:
Run the generator set once a month whenever possible.

Table of Contents

Other manuals for Kohler 14EKOZD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 14EKOZD and is the answer not in the manual?

Kohler 14EKOZD Specifications

General IconGeneral
BrandKohler
Model14EKOZD
CategoryPortable Generator
LanguageEnglish

Related product manuals