OPERATION OPERATION
3-70
5. After warm-up has completed, check gauges and caution
lamps for proper operation. If any abnormality is found,
repair it.
Continue to run the engine at low load until engine water
temperature gauge (2) falls within the white range (Moni-
tor Panel Spec.) or green range (Gauge Panel Spec.).
6. Check that there is no abnormal exhaust gas color, noise,
or vibretion. If any abnormality is found, repair it.
STOPPING ENGINE
NOTICE
If the engine is abruptly stopped before it has cooled
down, engine life may be greatly shortened. Consequently,
do not abruptly stop the engine apart from an emergency.
In particular, if the engine has overheated, do not abruptly
stop it but run it at medium speed to allow it to cool gradu-
ally, then stop it.