43
7 Maintenance
7-2 Replacing the fluorescent light
How to replace the fluorescent light
•Before replacing the fluorescent light, be sure to turn OFF the main power
switch and unplug the power cord from the receptacle.
•Gently open the fluorescent light cover.
•The florescent light is hot just after the power switch is turned off.
Wait until it cools down and then replace it with a new one of the same
type (straight tube 20W / 100V).
•When replacing parts, be sure to use parts of the correct specifications.
Never use parts other than the specified ones.
•Strictly refrain from disassembly and repair of parts which are not indicated
in this manual, as well as settings and remodelling.
1 Be sure to turn OFF the main power
switch and unplug the power cord
from the receptacle.
2 Remove the screws off the back
cover (see at right). Hold the knob
and gently open the cover.
3 Push one end of the fluorescent
light in the direction of the socket.
The other end of the fluorescent
light will be detached from the
opposite socket.
4 Install a new fluorescent light in the
reverse order.
•It is recommended to replace the glow lamp at the same time.
MEMO
Screws
Cover
Knob
Fluorescent light
(straight tube 20W/100V)
Glow lamp (FG-1E)
Push in this direction