7 Maintenance
7-5 Replacing the rifle unit microswitch
How to replace the microswitch
•Before replacing the microswitch of the rifle unit’s trigger, be sure to turn
OFF the main power switch and unplug the power cord from the receptacle.
•When replacing parts, be sure to use parts of the correct specifications.
Never use parts other than the specified ones.
•Strictly refrain from disassembly and repair of parts which are not indicated
in this manual, as well as settings and remodelling.
1 Be sure to turn OFF the main power
switch and unplug the power cord
from the receptacle.
2 Remove the screws (see at right)
and detach the cover of the trigger.
3 Detach the microswitch.
4 Disconnect the wires from the
microswitch.
A : M5 x 25L ...................... 2
B : M4 x 30L ...................... 2
C : M4 x 8 L
(no cap nut)
.... 4
D : M4 x 10L ...................... 1
Cover
A
B
C
D
Wire (black)
Wire (gray)
Microswitch
5
To fit the microswitch again
Fit a new microswitch in the reverse order. Be careful not to get the wires
caught.
6 Place and fix the cover (detached in Step 2 above) back into position.
7 Take the steps in “5-1 Checking the game performance (self test)” on page 23
and the step in “I/O CHECK”on page 25.