3.1 Checking the condition upon delivery
1. On transfer of goods, check each packaging unit for damage.
2. In the event of in-transit damage, assess the exact damage, document it and
notify KSB or the supplying dealer (as applicable) and the insurer about the
damage in writing immediately.
3.2 Transport
The automatic control unit must be shut down for transport.
Table4: Ambient conditions for transport
Ambient condition Value
Relative humidity Max. 80% (no condensation)
Ambient temperature -10°C to + 70°C
CAUTION
Improper transport
Damage to the automatic control unit!
The automatic control unit must always be transported properly and in its
original packaging.
For transport, observe the transport instructions on the original packaging.
Do not throw the automatic control unit.
1. Unpack the automatic control unit upon receipt and check for in-transit
damage.
2. Report any in-transit damage to the manufacturer immediately.
3. Dispose of packaging material in accordance with local regulations.
3.3 Storage
If the ambient conditions for storage are met, the automatic control unit will give
reliable service even after a prolonged period of storage.
CAUTION
Damage during storage by humidity, dirt or vermin
Corrosion/contamination of automatic control unit!
For outdoor storage, cover the (packed or unpacked) automatic control unit
and accessories with waterproof material.
Table5: Ambient conditions for storage
Ambient condition Value
Relative humidity Max. 80% (no condensation)
Ambient temperature -10°C to + 70°C
Store the automatic control unit under dry and vibration-free conditions, if
possible in its original packaging.
Store the automatic control unit in a dry room where the level of atmospheric
humidity is as constant as possible.
Prevent excessive fluctuations in atmospheric humidity (see table on ambient
conditions for storage).
If properly stored indoors, the equipment is protected for a maximum of 12months.

Other manuals for KSB Controlmatic E.2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KSB Controlmatic E.2 and is the answer not in the manual?

KSB Controlmatic E.2 Specifications

General IconGeneral
BrandKSB
ModelControlmatic E.2
CategoryControl Unit
LanguageEnglish

Related product manuals