53REGULAR CHECKS AND MAINTENANCE WORK
A Do not operate the engine without coolant.
A To fill the radiator system use fresh water and anti-
freeze fluid.
A When the anti-freeze is mixed with water, the anti-
freeze mixing ratio must be less than 50%.
A Tighten the radiator cap properly. If the cap is loosely
or not properly fitted, overheating of the engine can
result due to coolant fluid loss.
BReplacing Fuel Hoses and Hose Clamps
Replace the hoses and clamps.
(See "Checking Fuel and Intake Air Line" in "EVERY 200
SERVICE HOURS")
BReplacing Intake Air line
Replace the hoses and clamps, if necessary.
(See "Checking Fuel and Intake Air Line" in "EVERY 200
SERVICE HOURS")
(1) Recovery tank (A) "FULL"
(B) "LOW"
Radiator 2.4 L (0.63 US gal.)
Reserve tank 0.6 L (0.16 US gal.)
(1) Fuel lines
(2) Clamp bands
(1) Hoses
(2) Hose clamps