C: Networking and Security
EDS Device Servers User Guide 165
Command Mode
The Modem Emulation’s Command mode supports the standard AT command set. For a
list of available commands from the serial or telnet login, enter AT?. Use ATDT, ATD, and
ATDP to establish a connection:
+++ Switches to command mode if entered from serial port during
connection.
AT? Help.
ATDT<Address Info> Establishes the TCP connection to socket (<IP>/<port>).
ATDP<Address Info> See ATDT.
ATD Like ATDT. Dials default connect mode remote address and
port.
ATO Switches to data mode if connection still exists. Vice versa to
'+++'.
ATEn Switches echo in command mode (off - 0, on - 1).
ATH Disconnects the network session.
ATI Displays modem information.
ATS0 = n Accept incoming connection. (n = 0: disable, n = 1: connect
automatically, n = 2+: connect with ATA command (basically
wait for the user or application to issue a command to "pick up
the phone")
ATQn Quiet mode (0 - enable results code, 1 - disable result codes)
ATVn Verbose mode (0 - numeric result codes, 1 - text result codes)
ATZ Restores the current state from the setup settings.
A/ Repeat last valid command.
These commands allow the EDS to emulate a modem. The EDS ignores valid AT
commands that do not apply to the EDS and sends an OK response code.
In Command mode, the EDS can make a connection to the remote host and using the
remote address and remote port information specified on the Tunnel – Connect Mode
page (see Tunnel – Connect Mode Page on page 63).
When making a connection from the EDS using an ATDT or ATDP command, full or
partial IP addresses can be used. If a partial IP address is used, the EDS uses the
remote address and port as configured in the Connect Mode settings.
For the following examples, we assume that the remote address is 192.168.16.10 and
the port is set to 10001 in the Connect mode settings:
Entering ATDT alone causes the EDS to connect to the IP address and remote
port configured in Connect Mode.
Entering ATDT 119.25.50 causes the EDS to assume the first octet in the IP
address and connects to the remote IP address 192.119.25.50, port 10001.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix EDS32PR and is the answer not in the manual?

Lantronix EDS32PR Specifications

General IconGeneral
CertificationUL/CUL, FCC, CE, TUV, C-Tick, GS, CB scheme, VCCI FCC Part 15 Statement Class A Device, ICES-003 Class A Device, C-Tick, VCCI, CE Marking, UL-CUL Mark, TUV-GS Mark, RoHS FCC CFR 47 Part 15 Subpart B, ICES-003 Issue 4, AS/NZS CISPR 22, VCCI V-3, EN55022, EN61000-3-2, EN61000-3-3, EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11
Networking standardsIEEE 802.3
Serial interface typeRS-232
Serial ports quantity32
Ethernet LAN data rates10, 100 Mbit/s
Cabling technology10/100Base-T(X)
USB 2.0 ports quantity0
Ethernet LAN (RJ-45) ports1
Security algorithmsSSH
Supported network protocolsHTTP, HTTPS, FTP, TFTP, Telnet, TCP, UDP, LPD, XML, DHCP, SSHv2, SSLv3, SNMPv2, AutoIP, RSS, ARP, ICMP, SYSLOG, AES, SMTP, DNS, BOOTP, Traceroute
Built-in processorIntel XScale IXP420
Processor frequency266 MHz
Compatible operating systemsWindows 98/ME/NT/2000/XP/Vista
Flash memory8 MB
RAM capacity64 MB
LED indicatorsLAN
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Input voltage100 - 240 V
SafetyUL 60950-1, CSA-22.2 No.60950-1-03, EN60950-1, CB Report - IEC 60950-1

Related product manuals