7: Network, Line, Tunnel, and Terminal Settings
EDS Device Servers User Guide 66
Tunnel – Connect
Mode Page
Settings
Description
Block Serial Data Select whether incoming block serial data should be discarded. This
setting is used for debugging purposes. Choices are:
On = discard all incoming serial data on the respective interface.
Off = do not discard all incoming serial data. (default)
Block Network Data Select whether incoming block network data should be discarded.
This setting is used for debugging purposes. Choices are:
On = discard all incoming network data on the respective interface.
Off = do not discard all incoming network data. (default)
TCP Keep Alive Specifies the number of milliseconds the EDS waits during an inactive
connection before checking the status of the connection. If the EDS
does not receive a response from the remote host, it drops that
connection.
Email on Connect Select whether email should be sent when a connection is made.
None = no email should be sent.
Email # = send an email corresponding to the tunnel number.
Email on Disconnect Select whether email should be sent when a connection is closed.
None = do not send an email
Email # = send an email corresponding to the tunnel number.
Tunnel – Disconnect Mode Page
If you click Disconnect Mode at the top of one of the Tunnel pages, the Tunnel –
Disconnect Mode page displays. Here you can select the disconnect method for the
tunnel selected at the top of the page. For more information about Disconnect mode, see
Disconnect Mode on page 163.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix EDS32PR and is the answer not in the manual?

Lantronix EDS32PR Specifications

General IconGeneral
CertificationUL/CUL, FCC, CE, TUV, C-Tick, GS, CB scheme, VCCI FCC Part 15 Statement Class A Device, ICES-003 Class A Device, C-Tick, VCCI, CE Marking, UL-CUL Mark, TUV-GS Mark, RoHS FCC CFR 47 Part 15 Subpart B, ICES-003 Issue 4, AS/NZS CISPR 22, VCCI V-3, EN55022, EN61000-3-2, EN61000-3-3, EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11
Networking standardsIEEE 802.3
Serial interface typeRS-232
Serial ports quantity32
Ethernet LAN data rates10, 100 Mbit/s
Cabling technology10/100Base-T(X)
USB 2.0 ports quantity0
Ethernet LAN (RJ-45) ports1
Security algorithmsSSH
Supported network protocolsHTTP, HTTPS, FTP, TFTP, Telnet, TCP, UDP, LPD, XML, DHCP, SSHv2, SSLv3, SNMPv2, AutoIP, RSS, ARP, ICMP, SYSLOG, AES, SMTP, DNS, BOOTP, Traceroute
Built-in processorIntel XScale IXP420
Processor frequency266 MHz
Compatible operating systemsWindows 98/ME/NT/2000/XP/Vista
Flash memory8 MB
RAM capacity64 MB
LED indicatorsLAN
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Input voltage100 - 240 V
SafetyUL 60950-1, CSA-22.2 No.60950-1-03, EN60950-1, CB Report - IEC 60950-1