7: Network, Line, Tunnel, and Terminal Settings
EDS Device Servers User Guide 63
Tunnel –
Accept Mode
Page Settings
Description
TCP Keep Alive Specify the number of milliseconds the EDS waits during an inactive
connection before checking the status of the connection. If the EDS
does not receive a response from the remote host, it drops that
connection.
Email on Connect Select whether an email is sent when a connection is made.
None = do not send an email.
Email # = send an email corresponding to the tunnel number.
Email on
Disconnect
Select whether an email corresponding to the tunnel number is sent
when a connection is closed.
None = do not send an email.
Email # = send an email corresponding to the tunnel number.
Password Enter a password that clients must send to the EDS within 30 seconds
from opening a network connection to enable data transmission.
The password can have up to 31 characters and must contain only
alphanumeric characters and punctuation. When set, the password sent
to the EDS must be terminated with one of the following: (a) 0x10 (LF),
(b) 0x00, (c) 0x13 0x10 (CR LF), or (d) 0x13 0x00.
Prompt for
Password
Indicate whether the user should be prompted for the password upon
connection.
On = prompt for a password upon connection.
Off = do not prompt for a password upon connection.
Tunnel – Connect Mode Page
Connect Mode determines how the EDS initiates a connection to a remote host or device.
If you click Connect Mode at the top of one of the Tunnel pages, the Tunnel – Connect
Mode page displays. Here you can select the method for starting a tunnel in Connect
mode and select other settings for the tunnel selected at the top of the page.
Any configuration changes you make on the displayed page apply to the tunnel you
selected at the top of this page. For example, if Tunnel 1 is selected, any configuration
changes you make apply to tunnel 1.
Under Current Configuration, both Remote Address and Remote Port have a Delete
link that lets you delete the remote address and port number shown. If you click this link,
a message tells you that your action may stop an active connection. Click OK to proceed
or Cancel to cancel the operation.
For more information about Connect mode, see Connect Mode on page 162.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix EDS32PR and is the answer not in the manual?

Lantronix EDS32PR Specifications

General IconGeneral
CertificationUL/CUL, FCC, CE, TUV, C-Tick, GS, CB scheme, VCCI FCC Part 15 Statement Class A Device, ICES-003 Class A Device, C-Tick, VCCI, CE Marking, UL-CUL Mark, TUV-GS Mark, RoHS FCC CFR 47 Part 15 Subpart B, ICES-003 Issue 4, AS/NZS CISPR 22, VCCI V-3, EN55022, EN61000-3-2, EN61000-3-3, EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11
Networking standardsIEEE 802.3
Serial interface typeRS-232
Serial ports quantity32
Ethernet LAN data rates10, 100 Mbit/s
Cabling technology10/100Base-T(X)
USB 2.0 ports quantity0
Ethernet LAN (RJ-45) ports1
Security algorithmsSSH
Supported network protocolsHTTP, HTTPS, FTP, TFTP, Telnet, TCP, UDP, LPD, XML, DHCP, SSHv2, SSLv3, SNMPv2, AutoIP, RSS, ARP, ICMP, SYSLOG, AES, SMTP, DNS, BOOTP, Traceroute
Built-in processorIntel XScale IXP420
Processor frequency266 MHz
Compatible operating systemsWindows 98/ME/NT/2000/XP/Vista
Flash memory8 MB
RAM capacity64 MB
LED indicatorsLAN
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Input voltage100 - 240 V
SafetyUL 60950-1, CSA-22.2 No.60950-1-03, EN60950-1, CB Report - IEC 60950-1

Related product manuals